Product Details:
Payment & Shipping Terms:
|
Drop Height: | 300mm To 1500mm | Max. Load: | 100kg |
---|---|---|---|
Max Sample Dimension: | W1000*H800*D1000mm | Standard: | ISTA 6A |
Drop Method: | Free Falling | Application: | Large Package |
High Light: | laboratory testing equipment,laboratory test equipment |
ISTA 6A Large Package Free Fall Drop Testing Machines
300~1500mm drop height, adjustable
The drop height can customized
The machine can add guardrail
With Limit switch for protection machine
Model
|
AS-DT-150
|
Max. Weight of Test Samples (Kg)
|
100
|
Height of Drop (mm)
|
300~1500
|
Max. Dimension of Test Sample WxHxD (mm)
|
1000x800x1000
|
Falling Floor Size WxHxD (mm)
|
1700x20x1200
|
Drop Method
|
Face, edge, angle
|
Test Bench External Dimension WxHxD (mm)
|
1700x2300x1200
|
Weight (Kg)
|
600
|
Customized Available Large Package Drop Test Machine/Falling Tester used to measure the dropping impact incidence when the package in using, transportation and decorating. Besides precision plane drop testing, it also can undertake edge and angle test to ensure the complete performance evaluation for the package.
During the products handling or transport process, there may be drop/ fall, which results in damage within the products. And this Drop Tester simulates the drop/ fall of a finished product to evaluate the damage. All the rhombohedrons, angles and faces of the products can be teste.
Operating procedures
1,Connection: connect the random power line to the three-phase power supply and connect it to the ground. The control box and the test machine are also used randomly.
2 ,Fall height adjustment: open the mainframe power supply, set the test height (method as follows), press the rise key to reach the set height; if stop in the midway, it must make it reach the set height before the reverse operation command can be executed;
3,Put the object on the work table and fix it with a fixed pole.
4,Press the rising key to raise the measured object to the set height.
5,Press the drop key to cause the working table to detached from the object in an instant, and the measured object is free to fall.
6,Press the reset button to restore the working state of the worktable.
7,Repeat the above steps if the test is repeated.
8,After testing: press the lower key to turn the work table to the lowest position to turn off the power button.
Contact Person: Lily Chen
Tel: +8613543715035
-70 to +150 Degree Climate Temperature Humidity Test Chamber Price
Walk-In Climate Test Chamber For Low High Temperature And Humidity Testing
HL-225-F High And Low Temperature Cycle Test Chamber Has Cyclical System
Walk-in Temperature Humidity Testing Room, Environmental Walk-in Chamber
Customized Walk In Climatic Test Chamber Environmental Test Equipment
20% - 98% Rh Walk In Climatic Stability Chamber Electronic For Auto Spare Parts
Sunshine Simulation Uv / Xenon Aging Room Walk In Stability Chamber For Color Fastness Test
Vertical Type Sine Shock Vibration Temperature Humidity Test Chamber
Electromagnetic Horizontal X / Y Axle vibration Test System 20 Kn Exiting Force
350000N Max Sine Force Vibration Measuring Instruments / Vibration Analysis Equipment
5 - 2000hz Vibration Test System 20kn Force With Vertical Horizontal Bench